solar pump station

solar pump station
Product Detailed
solar pump station is intergrated device for the split close loop solar heating system.
ApplicationUsed to control the flow of the liquid between the collector and the storage and back
External dimension (HxWxD)488.7x275x154.5mm
Max. permitted pressure10 bar
Max permitted temperature100 °C
Max environment temperature+40 °C
Pipe connections of left wayG 1/2" male thread
Pipe connections of right wayG 1/2" female thread integrated with G 3/4" male thread
Safety devices
Security valveresponse at 3bar or 6 bar
Air  separator with bleeder valveG1 1/2" male
Manometer0 to 10 bar
Thermometer0 to 200°C
Circulation pump
Max. discharge flow2.5m³/h
Max. pump discharge6 m
Max. operating pressure10 bar
Medium temperature-25 °C  +110 °C
Voltage220V/60Hz or 110V/ 50Hz
Shut-off and display units
Stop ball valve with security valve on the left wayG 1"
Multifunction Ball valve integrated with check valve with filling valve on the right wayG 1"
Filling valveG 1/2" male with stop
Flow meter
Display/ setting range3 to 12 l/ min
ApplicationThe flowmeter is an adjustable rotameter with quantity restriction. The display and adjustment range is from 3 to 12 l/min  The rotameter enables the flow rate to be displayed very precisely.  The gauge-glass is made of shatter-proof glass with brass casing. The gauge is generally installed in the vertical position. 
Insulation
Material for back and front casingBlack EPP Foam
Installation
InstallationWall mounted in the vertical position
Regulation
controllerSR868C6 with 3 pieces temperature sensors (1pc PT1000, 2pcs of 10K) or SR618C with 6pcs of temperature sensors(2pc PT1000, 4pcs of 10K)
ApplicationTemperature difference control pump, electriic element, anti-freeze etc reactivity (on/off) automatically by preset memory in the control.


Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.